Angle Anatomy and Glaucoma in Patients With Boston Keratoprosthesis

Silva RN, Taniguchi E, Cruzat A, Paschalis E, Pasquale L, Colby K, Dohlman C, Chodosh J, Shen L. Angle Anatomy and Glaucoma in Patients With Boston Keratoprosthesis. Cornea. 2020;39(6):713–719.
See also: Cornea, Glaucoma, June 2020, All, 2020

Abstract

PURPOSE: To quantitatively analyze the angle anatomy in eyes with a Boston type 1 keratoprosthesis (KPro) using anterior segment optical coherence tomography (AS-OCT) and to assess the diagnostic ability of AS-OCT in KPro-associated glaucoma. METHODS: AS-OCT (RTVue) images from KPro eyes with and without glaucoma were reviewed. The angle opening distance at 500 μm from the scleral spur (AOD500), trabecular-iris angle at 500 μm from the scleral spur (TIA500), and trabecular-iris surface area at 500 μm from the scleral spur (TISA500) were measured by 2 observers masked to the diagnosis. The measurements for each visible quadrant were compared between KPro eyes with and without glaucoma. RESULTS: Twenty-two eyes with glaucoma and 17 eyes without glaucoma from 39 patients with KPro were included. Of the 4 quadrants imaged, the temporal angle was the most visible (79.5%) and angle measurements of the temporal quadrant were the only ones that differentiated the 2 groups: the mean AOD500, TIA500, and TISA500 were significantly lower in KPro eyes with glaucoma than without glaucoma (388.2 ± 234.4 μm vs. 624.5 ± 310.5 μm, P = 0.02; 26.1 ± 14.0 degrees vs. 39.1 ± 17.1 degrees, P = 0.03; and 0.15 ± 0.09 mm vs. 0.23 ± 0.12 mm, P = 0.03; respectively). The highest area under the receiver operating characteristic curve for detecting glaucoma was 0.75 for temporal TIA500 (95% confidence interval 0.57-0.94, P = 0.02) with 50% specificity at 80% of sensitivity and a cutoff value of 37 degrees. CONCLUSIONS: The temporal angle was the most visible on AS-OCT in eyes with a KPro. Significant narrowing of the temporal angle detected on AS-OCT was associated with glaucoma in these eyes.
Last updated on 03/06/2023