Publications

2021

Bouffard M, M Mallery R, Liao Y, Torun N. Variation in Evolving Optic Neuritis. J Neuroophthalmol. 2021;41(4):476–479.
BACKGROUND: The typical natural history of optic neuritis is subjected to important exceptions. Recognition of these exceptions has led to valuable insights regarding specific etiologies of optic neuritis. Exceptions to the natural history of recovering optic neuritis are well-defined (e.g., chronic relapsing inflammatory optic neuropathy), but exceptions to the natural history of evolving optic neuritis are less so. METHODS: Medical records of patients illustrating an atypical course of evolving optic neuritis were reviewed in a retrospective manner. Each patient was treated by at least one of the authors. RESULTS: Four patients were identified who illustrated an atypical natural history of incipient optic neuritis. Diagnoses included idiopathic optic neuritis, seropositive neuromyelitis optica spectrum disease, anti-myelin oligodendrocyte glycoprotein antibody disease, and multiple sclerosis in 1 patient each. Features of interest included an atypical temporal relationship between development of pain and onset of clinical optic neuropathy, an unusually protracted duration of pain, and an unusually long duration of worsening optic neuropathy before stabilization. CONCLUSIONS: This case series illustrates the substantial clinical heterogeneity which may be observed in the evolution of optic neuritis. The temporal relationship between development of pain and onset of clinical optic neuropathy, the duration of pain, and duration of worsening optic neuropathy before stabilization are all subjected to significant variability. Although most patients with optic neuritis present with painful vision loss which progresses over 1 week or less, careful attention to the exceptions described herein may facilitate earlier recognition of diagnostically challenging cases.
Zhu RL, Fang Y, Yu HH, Chen D, Yang L, Cho KS. Absence of ephrin-A2/A3 increases retinal regenerative potential for Müller cells in Rhodopsin knockout mice. Neural Regen Res. 2021;16(7):1317–1322.
Müller cells (MC) are considered dormant retinal progenitor cells in mammals. Previous studies demonstrated ephrin-As act as negative regulators of neural progenitor cells in the retina and brain. It remains unclear whether the lack of ephrin-A2/A3 is sufficient to promote the neurogenic potential of MC. Here we investigated whether the MC is the primary retinal cell type expressing ephrin-A2/A3 and their role on the neurogenic potential of Müller cells. In this study, we showed that ephrin-A2/A3 and their receptor EphA4 were expressed in retina and especially enriched in MC. The level of ephrinAs/EphA4 expression increased as the retina matured that is correlated with the reduced proliferative and progenitor cell potential of MC. Next, we investigated the proliferation in primary MC cultures isolated from wild-type and A2-/- A3-/- mice by 5-ethynyl-2'-deoxyuridine (EdU) incorporation. We detected a significant increase of EdU+ cells in MC derived from A2-/- A3-/- mice. Next, we investigated the role of ephrin-A2/A3 in mice undergoing photoreceptor degeneration such as Rhodopsin knockout (Rho-/-) mice. To further evaluate the role of ephrin-A2/A3 in MC proliferation in vivo, EdU was injected intraperitoneally to adult wild-type, A2-/- A3-/- , Rho-/- and Rho-/- A2-/- A3-/- mice and the numbers of EdU+ cells distributed among different layers of the retina. EphrinAs/EphA4 expression was upregulated in the retina of Rho-/- mice compared to the wild-type mice. In addition, cultured MC derived from ephrin-A2-/- A3-/- mice also expressed higher levels of progenitor cell markers and exhibited higher proliferation potential than those from wild-type mice. Interestingly, we detected a significant increase of EdU+ cells in the retinas of adult ephrin-A2-/- A3-/- mice mainly in the inner nuclear layer; and these EdU+ cells were co-localized with MC marker, cellular retinaldehyde-binding protein, suggesting some proliferating cells are from MC. In Rhodopsin knockout mice (Rho-/- A2-/- A3-/- mice), a significantly greater amount of EdU+ cells were located in the ciliary body, retina and RPE than that of Rho-/- mice. Comparing between 6 and 12 weeks old Rho-/- A2-/- A3-/- mice, we recorded more EdU+ cells in the outer nuclear layer in the 12-week-old mice undergoing severe retinal degeneration. Taken together, Ephrin-A2/A3 are negative regulators of the proliferative and neurogenic potentials of MC. Absence of ephrin-A2/A3 promotes the migration of proliferating cells into the outer nuclear layer and may lead to retinal cell regeneration. All experimental procedures were approved by the Animal Care and Use Committee at Schepens Eye Research Institute, USA (approval No. S-353-0715) on October 24, 2012.
Carreno-Galeano JT, Dohlman T, Kim S, Yin J, Dana R. A Review of Ocular Graft-versus-Host Disease: Pathophysiology, Clinical Presentation and Management. Ocul Immunol Inflamm. 2021;:1–10.
Graft-versus-host disease is a common complication following allogeneic hematopoetic stem cell transplantation that can affect multiple organ systems, including the eyes. Ocular GVHD (oGVHD) is characterized by a T cell-mediated immune response that leads to immune cell infiltration and inflammation of ocular structures, including the lacrimal glands, eyelids, cornea and conjunctiva. oGVHD has a significant negative impact on visual function and quality of life and successful management requires a multi-disciplinary approach with frequent monitoring. Here, we review the pathophysiology and clinical presentation of oGVHD, along with current therapeutic strategies based on our clinical experience and the reported literature.
Bosque L, Yamarino C, Salcedo N, Schneier A, Gold R, Blumenfeld L, Hunter D. Evaluation of the blinq vision scanner for detection of amblyopia and strabismus. J AAPOS. 2021;
PURPOSE: To report the results of a clinical study designed to evaluate the accuracy of the blinq pediatric vision scanner, which detects amblyopia and strabismus directly by means of retinal polarization scanning, unlike other vision screening devices, which infer possible disease based on detection of refractive risk factors. METHODS: Subjects 1-20 years of age were prospectively enrolled in this cross-sectional diagnostic accuracy study with planned enrollment of 200. All enrolled subjects were tested by individuals masked to the diagnosis, followed by complete ophthalmologic examination by pediatric ophthalmologists masked to the screening result. Patients previously treated for amblyopia or strabismus were analyzed separately. RESULTS: The study cohort comprised 193 subjects, 53 of whom had been previously treated, leaving 140 treatment-naïve subjects, including 65 (46%) with amblyopia or strabismus, 11 (8%) with risk factors/suspected binocular vision deficit without amblyopia/strabismus, and 64 (46%) controls. Sensitivity was 100%, with all 66 patients with referral-warranted ocular disease referred. Five patients with intermittent strabismus receiving pass results were deemed "acceptable pass" when considering patient risk factors and amblyogenic potential. Specificity was 91%, with 7 incorrect referrals. Subanalysis of children aged 2-8 years (n = 92) provided similar results (sensitivity 100%; specificity 89%). CONCLUSIONS: In this study cohort, the blinq showed very high sensitivity and specificity for detecting referral-warranted amblyopia and strabismus. Implementation of the device in vision screening programs could lead to improved rates of disease detection and reduction in false referrals.
McKay M, Apostolopoulos N, Dahrouj M, Nguyen H, Reddy A, Blazes M, Lacy M, Pepple K, Lee A, Lee C. Assessing the Uniformity of Uveitis Clinical Concepts and Associated ICD-10 Codes Across Health Care Systems Sharing the Same Electronic Health Records System. JAMA Ophthalmol. 2021;
Importance: Big data studies may allow for the aggregation of patients with rare diseases such as uveitis to answer important clinical questions. Standardization of uveitis-related variables will be necessary, including the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (ICD-10) codes used to identify patients of interest. There are currently limited data on the uniformity of diagnosis mapping to ICD-10 codes for uveitis diagnoses among different health systems. Objective: To assess the degree of uniformity in mapping of uveitis clinical concepts to ICD-10 codes across health care systems using the same electronic health record (EHR) system. Design, Setting, and Participants: This multicenter survey study was conducted between September 14 and October 9, 2020, at 5 academic health care systems that use the Epic EHR. Researchers from the University of Washington, Harvard University, Stanford University, Yale University, and the University of California, San Francisco queried 54 uveitis-related diagnostic terms and recorded the associated ICD-10 codes. Main Outcomes and Measures: The degree of uniformity for uveitis clinical concepts and associated ICD-10 codes. Results: Fifty-four uveitis-related diagnostic terms were queried within the Epic EHR at 5 different health care systems. There was perfect agreement among all 5 centers for 52 of the 54 diagnostic terms. Two diagnostic terms had differences in ICD-10 coding: juvenile idiopathic arthritis associated chronic uveitis and intermediate uveitis. Intermediate uveitis was associated with codes H20.1x (ICD-10 description: chronic iridocyclitis) or H20.9 (ICD-10 description: unspecified iridocyclitis) in 3 centers while being associated with code H30.2x (ICD-10 description: posterior cyclitis) at the 2 remaining centers. The discrepancies appear to be related to a recent update in diagnostic mapping in the Epic EHR. Conclusions and Relevance: This study suggests that ICD-10 code mapping to uveitis diagnostic terminology appears to be highly uniform at different centers with the Epic EHR. However, temporal changes in diagnosis mapping to ICD-10 codes and a lack of 1-to-1 mapping of diagnosis to ICD-10 code add additional sources of complexity to the interpretation of big data studies in uveitis.
Ebrahimiadib N, Fadakar K, Riazi-Esfahani H, Zarei M, Maleki A, Bojabadi L, Ahmadi A, Look-Why S, Foster CS. COVID-19 and Immunosuppressive Therapy in Ocular Inflammatory Disease, a Telemedicine Survey. Ocul Immunol Inflamm. 2021;:1–7.
Purpose: Determine the risk of immunomodulatory therapy (IMT) for COVID-19 infection morbidity.Method: A telemedicine survey on patients of a referral uveitis clinic was performed. Signs of infection, habits, and hospitalizations during the 7 months of the COVID-19 pandemic prior to the study date were recorded. Suggestive findings in chest CT scan and/or positive RT-PCR were considered as confirmed COVID-19 infection while those with only suggestive symptoms were considered as suspected cases. Risk factors including sanitary measures and IMT were compared between patients with confirmed cases and patients without infection.Result: 694 patients were included. Eight patients were identified as confirmed cases and 22 patients as suspected cases of COVID-19 infection. Close contact with infected persons was the only significant risk factor for contracting COVID-19.Conclusion: Using IMT did not affect hospitalization and/or ICU admission and can thus be continued during the pandemic, provided that instructions for preventive measures are followed.
Soeken T, Ross A, Kohane D, Kuang L, Legault G, Caldwell M, Brundridge W, Merkley M, Ciolino J, Townley R. Dexamethasone-Eluting Contact Lens for the Prevention of Postphotorefractive Keratectomy Scar in a New Zealand White Rabbit Model. Cornea. 2021;40(9):1175–1180.
PURPOSE: To evaluate the safety and efficacy of an experimental dexamethasone-eluting contact lens (DCL) for the prevention of postphotorefractive keratectomy (PRK) corneal haze in a New Zealand White (NZW) rabbit model. METHODS: Both eyes of 29 NZW rabbits underwent PRK. The rabbits were randomized to one of the 5 study arms for 4 weeks: tarsorrhaphy only, tarsorrhaphy and bandage contact lens (BCL) replaced weekly, tarsorrhaphy and BCL for 1 week plus topical 0.1% dexamethasone ophthalmic solution (drops) for 4 weeks, tarsorrhaphy and BCL replaced weekly plus topical dexamethasone for 4 weeks, and tarsorrhaphy and DCL changed weekly for 4 weeks. Each week for 4 consecutive weeks postoperatively, the tarsorrhaphies were opened, the eyes underwent evaluation and imaging, and the tarsorrhaphies were replaced. Contact lenses were cultured on removal. Central corneal haze was assessed weekly with corneal densitometry. After 4 weeks, the animals were killed, and the eyes were enucleated for histopathologic analysis. RESULTS: The tarsorrhaphy only group displayed more haze with a greater change in optical densitometry from pre-op compared with the other treatment groups. There was no difference between the DCL group and the groups receiving a BCL and dexamethasone drops in densitometry or histopathology. No NZW rabbits developed clinical signs of infection, and cultures from DCLs and BCLs grew similar organisms. CONCLUSIONS: In the post-PRK rabbit model, DCLs worn weekly for 4 weeks were safe and as effective at preventing corneal haze as 0.1% dexamethasone drops applied 4 times a day for 4 weeks.
Pundlik S, Baliutaviciute V, Moharrer M, Bowers A, Luo G. Home-Use Evaluation of a Wearable Collision Warning Device for Individuals With Severe Vision Impairments: A Randomized Clinical Trial. JAMA Ophthalmol. 2021;139(9):998–1005.
Importance: There is scant rigorous evidence about the real-world mobility benefit of electronic mobility aids. Objective: To evaluate the effect of a collision warning device on the number of contacts experienced by blind and visually impaired people in their daily mobility. Design, Setting, and Participants: In this double-masked randomized clinical trial, participants used a collision warning device during their daily mobility over a period of 4 weeks. A volunteer sample of 31 independently mobile individuals with severe visual impairments, including total blindness and peripheral visual field restrictions, who used a long cane or guide dog as their habitual mobility aid completed the study. The study was conducted from January 2018 to December 2019. Interventions: The device automatically detected collision hazards using a chest-mounted video camera. It randomly switched between 2 modes: active mode (intervention condition), where it provided alerts for detected collision threats via 2 vibrotactile wristbands, and silent mode (control condition), where the device still detected collisions but did not provide any warnings to the user. Scene videos along with the collision warning information were recorded by the device. Potential collisions detected by the device were reviewed and scored, including contacts with the hazards, by 2 independent reviewers. Participants and reviewers were masked to the device operation mode. Main Outcomes and Measures: Rate of contacts per 100 hazards per hour, compared between the 2 device modes within each participant. Modified intention-to-treat analysis was used. Results: Of the 31 included participants, 18 (58%) were male, and the median (range) age was 61 (25-73) years. A total of 19 participants (61%) had a visual acuity (VA) of light perception or worse, and 28 (90%) reported a long cane as their habitual mobility aid. The median (interquartile range) number of contacts was lower in the active mode compared with silent mode (9.3 [6.6-14.9] vs 13.8 [6.9-24.3]; difference, 4.5; 95% CI, 1.5-10.7; P < .001). Controlling for demographic characteristics, presence of VA better than light perception, and fall history, the rate of contacts significantly reduced in the active mode compared with the silent mode (β = 0.63; 95% CI, 0.54-0.73; P < .001). Conclusions and Relevance: In this study involving 31 visually impaired participants, the collision warnings were associated with a reduced rate of contacts with obstacles in daily mobility, indicating the potential of the device to augment habitual mobility aids. Trial Registration: ClinicalTrials.gov Identifier: NCT03057496.
Yoon M, Habib L. Spheno-Orbital Dermoid Masquerading as Recurrent Orbital Abscess. Ophthalmic Plast Reconstr Surg. 2021;37(6):e213-e215.
A 10-month-old girl presented with eyelid edema and erythema that did not improve with systemic antibiotics. Due to a lack of improvement, MRI was performed to avoid ionizing radiation from CT. An orbital abscess was recognized and drained. However, the abscess recurred 2 times. CT scan was performed and a tract in the sphenoid bone helped to diagnose a congenital dural sinus tract with dermoid. Definitive surgery was performed with neurosurgery to remove the entire tract including cutaneous connection. CT scan proved critical to diagnosis and should be considered in infants in select cases despite the concern for ionizing radiation in this vulnerable age group.