Silva RN, Taniguchi E, Cruzat A, Paschalis E, Pasquale L, Colby K, Dohlman C, Chodosh J, Shen L. Angle Anatomy and Glaucoma in Patients With Boston Keratoprosthesis. Cornea. 2020;39(6):713–719.
PURPOSE: To quantitatively analyze the angle anatomy in eyes with a Boston type 1 keratoprosthesis (KPro) using anterior segment optical coherence tomography (AS-OCT) and to assess the diagnostic ability of AS-OCT in KPro-associated glaucoma. METHODS: AS-OCT (RTVue) images from KPro eyes with and without glaucoma were reviewed. The angle opening distance at 500 μm from the scleral spur (AOD500), trabecular-iris angle at 500 μm from the scleral spur (TIA500), and trabecular-iris surface area at 500 μm from the scleral spur (TISA500) were measured by 2 observers masked to the diagnosis. The measurements for each visible quadrant were compared between KPro eyes with and without glaucoma. RESULTS: Twenty-two eyes with glaucoma and 17 eyes without glaucoma from 39 patients with KPro were included. Of the 4 quadrants imaged, the temporal angle was the most visible (79.5%) and angle measurements of the temporal quadrant were the only ones that differentiated the 2 groups: the mean AOD500, TIA500, and TISA500 were significantly lower in KPro eyes with glaucoma than without glaucoma (388.2 ± 234.4 μm vs. 624.5 ± 310.5 μm, P = 0.02; 26.1 ± 14.0 degrees vs. 39.1 ± 17.1 degrees, P = 0.03; and 0.15 ± 0.09 mm vs. 0.23 ± 0.12 mm, P = 0.03; respectively). The highest area under the receiver operating characteristic curve for detecting glaucoma was 0.75 for temporal TIA500 (95% confidence interval 0.57-0.94, P = 0.02) with 50% specificity at 80% of sensitivity and a cutoff value of 37 degrees. CONCLUSIONS: The temporal angle was the most visible on AS-OCT in eyes with a KPro. Significant narrowing of the temporal angle detected on AS-OCT was associated with glaucoma in these eyes.
Amamoto R, Zuccaro E, Curry N, Khurana S, Chen HH, Cepko C, Arlotta P. FIN-Seq: transcriptional profiling of specific cell types from frozen archived tissue of the human central nervous system. Nucleic Acids Res. 2020;48(1):e4.
Thousands of frozen, archived tissue samples from the human central nervous system (CNS) are currently available in brain banks. As recent developments in RNA sequencing technologies are beginning to elucidate the cellular diversity present within the human CNS, it is becoming clear that an understanding of this diversity would greatly benefit from deeper transcriptional analyses. Single cell and single nucleus RNA profiling provide one avenue to decipher this heterogeneity. An alternative, complementary approach is to profile isolated, pre-defined cell types and use methods that can be applied to many archived human tissue samples that have been stored long-term. Here, we developed FIN-Seq (Frozen Immunolabeled Nuclei Sequencing), a method that accomplishes these goals. FIN-Seq uses immunohistochemical isolation of nuclei of specific cell types from frozen human tissue, followed by bulk RNA-Sequencing. We applied this method to frozen postmortem samples of human cerebral cortex and retina and were able to identify transcripts, including low abundance transcripts, in specific cell types.
Shakhmantsir I, Dooley S, Kishore S, Chen D, Pierce E, Bennett J, Sehgal A. RNA Splicing Factor Mutations That Cause Retinitis Pigmentosa Result in Circadian Dysregulation. J Biol Rhythms. 2020;35(1):72–83.
Circadian clocks regulate multiple physiological processes in the eye, but their requirement for retinal health remains unclear. We previously showed that Drosophila homologs of spliceosome proteins implicated in human retinitis pigmentosa (RP), the most common genetically inherited cause of blindness, have a role in the brain circadian clock. In this study, we report circadian phenotypes in murine models of RP. We found that mice carrying a homozygous H2309P mutation in () display a lengthened period of the circadian wheel-running activity rhythm. We show also that the daily cycling of circadian gene expression is dampened in the retina of H2309P mice. Surprisingly, molecular rhythms are intact in the eye cup, which includes the retinal pigment epithelium (RPE), even though the RPE is thought to be the primary tissue affected in this form of RP. Downregulation of , another RNA splicing factor implicated in RP, leads to period lengthening in a human cell culture model. The period of circadian bioluminescence in primary fibroblasts of human RP patients is not significantly altered. Together, these studies link a prominent retinal disorder to circadian deficits, which could contribute to disease pathology.
Cohen L, Habib L, Yoon M. Post-traumatic enophthalmos secondary to orbital fat atrophy: a volumetric analysis. Orbit. 2020;39(5):319–324.
PURPOSE: To investigate via volumetric analysis whether orbital fat atrophy occurs in late post-traumatic enophthalmos. METHODS: An IRB-approved retrospective cohort study identified patients with diagnoses of both orbital fracture and enophthalmos with a CT orbits >3 months after injury. Exclusion criteria were surgical repair, other orbital disease or surgery, adjacent sinus disease, and an abnormal contralateral orbit. Images were analyzed using OsiriX imaging software (v.9.0.2, Pixmeo, Switzerland). Total orbital volume and orbital fat volume for the fractured and normal contralateral orbits were measured via three-dimensional volume rendering assisted region-of-interest computation. Enophthalmos was measured radiographically. Paired samples -tests were used to compare orbital fat and total orbital volumes between the fractured and normal contralateral orbits. RESULTS: Thirteen patients met the inclusion criteria. The numbers of patients with each fracture pattern were floor (4), medial wall (4), floor/medial wall (3), zygomaticomaxillary complex (floor+lateral wall) (1), zygomaticomaxillary complex+medial (inferior/medial/lateral walls) (1). Mean time from injury to CT scan was 21.8 ± 16.3 months. Comparing the fractured and normal contralateral orbits, there was a statistically significant decrease in orbital fat volume (mean difference 0.9 ml (14.2%), = .0002) and increase in total orbital volume (mean difference 2.0 ml (7.0%), = .0001). One ml orbital volume change was responsible for 0.83 mm enophthalmos. CONCLUSIONS: In addition to an increase in total orbital volume, orbital fat loss occurs with late post-traumatic enophthalmos due to unrepaired fractures. This suggests correction of bony change alone may be insufficient in some cases, and the use of custom implants may compensate for fat atrophy.
Bakshi S, Graney J, Paschalis E, Agarwal S, Basu S, Iyer G, Liu C, Srinivasan B, Chodosh J. Design and Outcomes of a Novel Keratoprosthesis: Addressing Unmet Needs in End-Stage Cicatricial Corneal Blindness. Cornea. 2020;39(4):484–490.
PURPOSE: The most commonly applied prosthetic devices for corneal blindness in the setting of severe cicatricial keratoconjunctivitis are the Boston keratoprosthesis type II and the modified osteo-odonto-keratoprosthesis, with these requiring either normal eyelid skin or a healthy cuspid tooth, respectively. For patients with neither attribute, we developed a new keratoprosthesis device combining positive aspects of both Boston keratoprosthesis type II and modified osteo-odonto-keratoprosthesis, which we have named the "Lux." METHODS: Short-term postoperative outcomes for the Lux keratoprosthesis, best-corrected visual acuity (BCVA), device retention, and complications, were examined in a retrospective case series of 9 eyes of 9 patients implanted at 4 centers. RESULTS: Seven of 9 (77.8%) eyes had cicatricial corneal blindness due to autoimmune disease and 2 (22.2%) from severe burns. Preoperative BCVA was ≤hand motions in all patients. Three (33.3%) had previously received at least 1 keratoprosthesis in the affected eye, and 4 (44.4%) had previously undergone ≥1 therapeutic keratoplasty. One patient had 19 previous eye surgeries. The mean duration of postoperative follow-up was 18.7 months (range 7-28 months). BCVA of ≥20/200 was achieved in all 9 patients, with 2 (22.2%) reaching 20/20 at the last examination, and all 9 (100%) of the devices were retained. One recipient developed a retinal detachment 2 months after implantation. Two (22.2%) patients required placement of a glaucoma drainage device. CONCLUSIONS: The Lux keratoprosthesis was developed for patients with severe cicatricial keratoconjunctivitis who were otherwise not candidates for existing keratoprosthesis designs. Short-term outcomes after implantation of the Lux keratoprosthesis were encouraging.
Koo E, Pineda R, Afshari N, Eghrari A. Learning Descemet Membrane Endothelial Keratoplasty: A Survey of U.S. Corneal Surgeons. Cornea. 2020;39(5):590–593.
PURPOSE: The transition to Descemet membrane endothelial keratoplasty (DMEK) is frequently challenging, requiring the adoption of new techniques, skills, and methods. We sought to draw on surgeons' initial experiences with DMEK to characterize the learning curve associated with this procedure and identify factors that could be linked to the frequency of primary graft failure (PGF) in the first 10 cases. METHODS: We invited corneal surgeons based in the United States who started performing the DMEK procedure within the past 2 years to answer a 12-question survey using an online survey platform. We analyzed quantitative and qualitative data. A Fisher exact test was used to determine whether preoperative approaches to preparation were associated with decreased PGF rates. RESULTS: A total of 100 US-based corneal surgeons replied from 34 of 50 states. Of these, 68% reported that DMEK comprised a majority of their endothelial keratoplasty cases. Approximately half of surgeons (52%) had performed more than 20 DMEK cases by the time of the survey, and 51% felt equally comfortable performing DMEK relative to Descemet stripping endothelial keratoplasty. Among the respondents, 37% answered that they had experienced PGF in the first 10 cases. Scrubbing in with an experienced colleague before surgery was associated with a decreased likelihood of at least one case of PGF (31%, P = 0.049), but not participation in a wet lab with an experienced instructor or mentor (38%, P = 0.50), nor having an eye bank representative present in the operating room (43%, P = 0.886). CONCLUSIONS: The collective experience of 100 surgeons beginning DMEK confirms the importance of mentorship and that the accompaniment of an experienced colleague during the learning curve is associated with lower rates of PGF.
Shoshany T, Michalak S, Staffa S, Chinn R, Bishop K, Hunter D. Effect of Primary Occlusion Therapy in Asymmetric, Bilateral Amblyopia. Am J Ophthalmol. 2020;211:87–93.
PURPOSE: Many bilateral amblyopia patients have asymmetric visual acuity (VA). There is no standard treatment for these patients, and outcomes have not been well described. Our goal is to compare VA outcomes in this group based on timing of occlusion therapy. DESIGN: Retrospective interventional comparative case series. METHODS: Setting: Institutional practice. PatientPopulation: Patients diagnosed with amblyopia at Boston Children's Hospital between 2010 and 2014. InclusionCriteria: VA ≥ 0.3 logMAR bilaterally by objective optotype-based measures, interocular difference (IOD) ≥ 0.18 logMAR, age 2-12 years. ExclusionCriteria: Loss to follow-up, managed surgically, deprivation amblyopia. Patients had either primary or secondary occlusion (primary = initiated when VA ≥ 0.3 logMAR bilaterally; secondary = initiated to correct residual IOD once VA improved to ≤0.18 logMAR in the stronger eye). ObservationProcedure: Patient demographics, VA, IOD, and stereopsis were compared between groups. OutcomeMeasures: VA improvement at 12-18 months and at last visits. RESULTS: Of 2,200 patients reviewed, 167 (7.6%) had asymmetric, bilateral amblyopia; 98 met inclusion and exclusion criteria. Patients were equally divided between primary (n = 50) and secondary (n = 48) occlusion groups. There were no differences in demographics, baseline VA, or IOD between groups (P ≥ .22), although the primary occlusion group had a higher proportion of strabismic amblyopia (P = .007). VA in both eyes, IOD, and stereopsis improved similarly between groups, even after stratifying by amblyopia subtype (P ≥ .48). The secondary occlusion group was more likely to achieve 20/30 bilaterally and IOD ≤ 1 line at 12-18 months (P ≤ .4), although this equalized by the last visit. CONCLUSION: In patients with asymmetric, bilateral amblyopia, VA improved by 4 lines in the weaker eye and 2 lines in the stronger eye, while IOD improved by 2 lines, irrespective of occlusion status. Primary occlusion thus provided no further benefit over spectacle correction alone.
Greiner J, Glonek T, Korb D, Lindsay M, Oliver P, Olson MC. Corneal Cryopreservation Using Glycerylphosphorylcholine-Enriched Medium. Cornea. 2020;39(3):370–375.
PURPOSE: To determine the effects of prolonged cryopreservation at subzero-degree temperatures on corneal transparency and histology after treatment with preservation medium containing the phosphodiester glycerylphosphorylcholine (GPC). METHODS: Rabbit corneas (n = 30) were immersed for 3 hours in K-Sol preservation medium containing 30 mM GPC. Three groups with 6 corneas each were refrigerated at -8°C for 2 weeks and liquid nitrogen temperature for 2 and 6 weeks, respectively. Two groups with 6 corneas each immersed in K-Sol preservation medium only were refrigerated at -8°C for 2 weeks and liquid nitrogen temperature for 6 weeks, respectively. Postthawing corneal transparency was measured on a grading scale after which corneas were prepared for and analyzed by light and transmission electron microscopy. RESULTS: All 3 groups of corneas preserved with GPC maintained a greater degree of corneal transparency compared with corneas preserved without GPC. The number of corneas retaining epithelial and endothelial layers increased in all groups where corneas were preserved in medium containing GPC, in contrast to corneas preserved in medium without GPC. Cytoplasmic vacuolization or nuclear damage was greater in corneas preserved without GPC. Similar findings were found in corneas stored at -8°C and liquid nitrogen temperatures. CONCLUSIONS: This study demonstrates a cryoprotective effect of corneas preserved in K-Sol containing the phosphodiester GPC at subzero-degree temperatures. In corneas immersed in preservation medium containing GPC, a higher degree of transparency is maintained and a lesser degree of histopathologic changes is observed with storage at both -8°C and in liquid nitrogen.
Gaier E, Tarabishy S, Bayers C, Wolkow N, Gardiner M, Lefebvre D, Grob S. Poor prognoses of open globe injuries with concomitant orbital fractures. Orbit. 2020;39(4):241–250.
PURPOSE: Orbital trauma, particularly with open globe injury, can have a wide range of visual outcomes, which can be difficult to predict at presentation. Clinical features on presentation may provide insight into visual prognosis. We hypothesized that patients with open globe injuries and concomitant orbital fractures have poorer visual outcomes than patients without orbital fractures. METHODS: We reviewed the charts of 77 patients with isolated open globe injuries (OG) and 76 patients with open globe injuries and concomitant orbital fractures (OGOF). Multivariate regression analysis was performed to assess the relative influence of individual presenting historical and clinical features on visual outcome. RESULTS: OGOF patients were more likely to have sustained blunt trauma than a sharp, penetrating injury compared to OG patients. Ocular wound locations were more posterior and likely to involve multiple zones in OGOF compared to OG patients. Among OGOF patients, orbital floor fractures were the most common and roof fractures were the least common, but the latter was associated with presenting NLP vision and multiple zone involvement. The presence of an orbital fracture independently increased the odds of subsequent evisceration/enucleation (OR: 4.6, 95% CI 1.3-20.1, = .0246) and NLP vision (OR: 6.81, 95% CI 2.42-21.85, = .0005) when controlling for zone, mechanism of injury, uveal prolapse and demographic variables. CONCLUSIONS: The presence of an orbital fracture independently confers a worse visual and ocular prognosis in patients with open globe injuries. Patients with open globe injuries in this category should be appropriately counseled.