MRI-based Neuropathy Score Reporting And Data System (NS-RADS): multi-institutional wider-experience usability study of peripheral neuropathy conditions among 32 radiology readers.

Chhabra, Avneesh, Flavio Duarte Silva, Bayan Mogharrabi, Mina Guirguis, Oganes Ashikyan, Michael Rasper, Eunhae Park, et al. 2024. “MRI-Based Neuropathy Score Reporting And Data System (NS-RADS): Multi-Institutional Wider-Experience Usability Study of Peripheral Neuropathy Conditions Among 32 Radiology Readers.”. European Radiology.

Abstract

OBJECTIVE: To determine the inter-reader reliability and diagnostic performance of classification and severity scales of Neuropathy Score Reporting And Data System (NS-RADS) among readers of differing experience levels after limited teaching of the scoring system.

METHODS: This is a multi-institutional, cross-sectional, retrospective study of MRI cases of proven peripheral neuropathy (PN) conditions. Thirty-two radiology readers with varying experience levels were recruited from different institutions. Each reader attended and received a structured presentation that described the NS-RADS classification system containing examples and reviewed published articles on this subject. The readers were then asked to perform NS-RADS scoring with recording of category, subcategory, and most likely diagnosis. Inter-reader agreements were evaluated by Conger's kappa and diagnostic accuracy was calculated for each reader as percent correct diagnosis. A linear mixed model was used to estimate and compare accuracy between trainees and attendings.

RESULTS: Across all readers, agreement was good for NS-RADS category and moderate for subcategory. Inter-reader agreement of trainees was comparable to attendings (0.65 vs 0.65). Reader accuracy for attendings was 75% (95% CI 73%, 77%), slightly higher than for trainees (71% (69%, 72%), p = 0.0006) for nerves and comparable for muscles (attendings, 87.5% (95% CI 86.1-88.8%) and trainees, 86.6% (95% CI 85.2-87.9%), p = 0.4). NS-RADS accuracy was also higher than average accuracy for the most plausible diagnosis for attending radiologists at 67% (95% CI 63%, 71%) and for trainees at 65% (95% CI 60%, 69%) (p = 0.036).

CONCLUSION: Non-expert radiologists interpreted PN conditions with good accuracy and moderate-to-good inter-reader reliability using the NS-RADS scoring system.

CLINICAL RELEVANCE STATEMENT: The Neuropathy Score Reporting And Data System (NS-RADS) is an accurate and reliable MRI-based image scoring system for practical use for the diagnosis and grading of severity of peripheral neuromuscular disorders by both experienced and general radiologists.

KEY POINTS: • The Neuropathy Score Reporting And Data System (NS-RADS) can be used effectively by non-expert radiologists to categorize peripheral neuropathy. • Across 32 different experience-level readers, the agreement was good for NS-RADS category and moderate for NS-RADS subcategory. • NS-RADS accuracy was higher than the average accuracy for the most plausible diagnosis for both attending radiologists and trainees (at 75%, 71% and 65%, 65%, respectively).

Last updated on 07/01/2024
PubMed